Humidistats and condensation controllers
Duct Humidistats: HG80, HG80-2,
room Humidistats: HG Mini, HG120
and the thermo-HumidistatDUO
OEM: hygro-modules
condensation control: FAS, FGO and FGS, HSF
Galltec+Mela humidistats for monitoring and controlling relative humidity feature an impressively simple, robust design that ensures a long service life.
The watertight POLYGA® measuring element, combined with a smart mechanism, provides reliable control signals. The benefits for you: reliability and high quality, all at a reasonable price.
More about humidistats »
-
HG80
Humidistat
series HG80with Polyga® humidity measuring element
scale range 30...100%rh
with one or two changeover contacts (HG80 or HG80-2)
version with internal adjusting knob available (HG80i)
-
HG120
Room Humidistat
series HG120with Polyga® measuring element
scale range 30...100%rh
with one or two changeover contacts (HG120 or HG120-2)
version with internal adjusting knob available (HG120i)
-
HGMini
Room Humidistat
series HGMiniwith Polyga® measuring element
scale range 30...100%rh
version with internal adjusting knob available (HGMini-i)
-
Hygroswitch
Room humidistat Hygroswitch
Room hygrostat
with Polyga® measuring element
scale range 30...100% RH
working range 35...95 %RH
-
HM80
Hygro Module HM80
with Polyga® measuring element
scale range 30...100%rh
OEM duct version
version with two changeover contacts available (HM80-2)
-
HM120
Hygro Module HM120
with Polyga® measuring element
scale range 30...100%rh
OEM room version
-
DUO1035
Room Hygro-thermostat DUO
scale range humidity 30...100%rh
scale range temperature 10..35°C
-
DUO1060
Room Hygro-Thermostat DUO
Scale range humidity: 30...10% rh
Scale range temperature: 10...60°C
-
FAS
Condensation controller - to prevent damage caused by condensation or high humidity
- Operating temperature 0...+60 °C
- Accuracy: ±3 % RH
- Robust
- Long-term stability
- Washable measuring element
- No external power supply required
- with Polyga® measuring element
- Changeover contact with silver contact
- Breaking capacity max. 48VAC
-
FAS 250VAC
Condensation controller to monitor the formation of condensed water
- Operating temperature 0...+60 °C
- Accuracy: ±3 % RH
- Robust
- Long-term stability
- Washable measuring element
- No external power supply required
- with Polyga® measuring element
- Changeover contact with silver contact
- breaking capacity max. 250VAC
-
FGO / FGS
Humidity sensor for condensation control
with capacitive Mela® humidity sensor element
for condensation control
with analogue output signal type FGO2.K/5
with switching output type FGS
-
HSF
Condensation detector IP65
Sensors for monitoring condensation are suitable for installation on cooling water pipes or cooled surfaces and monitor whether the temperature of the direct surroundings falls below the dew point.
- Operating temperature -20...+70 °C
- Accuracy: ±2 % RH
- IP65 protection
- Dynamic
- Analogue - and switching output
- Signal output 0...10V
- Sensor element: capazitive